TEOS 300

10 - 80 kVA

DSP technology guarantees high performance • Output power factor 1.0 • Active power factor correction in all phases • Dual Inputs • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving • Emergency power off function (EPO)

Mostrar Más

Áreas de Uso

Características Generales

TEOS 300
  • DSP technology guarantees high performance
  • Output power factor 1.0
  • Active power factor correction in all phases
  • Dual Inputs
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving
  • Emergency power off function (
  • EPO)
  • Adjustable charging current
  • Very powerful charger
  • Optional parallel operation with common battery
  • High overload capability
  • Adjustable battery design
  • Optional 4.3”touch LCD
TECHNICIAL SPECIFICATIONS
Phase3 phase in / 3 phase out
Capacity10kVA / 10kW
Parallel capability3
INPUT
Nominal Voltage3 x 400VAC (3F+N)
Nominal Voltage | Input voltage range190-520VAC (3-Phase) @ 50% load
305-478VAC (3-Phase) @ 100% load
Frequency range46~54Hz or 56~64Hz
Power factor≥ 0.99 @ 100% load
OUTPUT
Output voltage3 x 360*/380/400/415 VAC (3F+N)
AC Voltage regulation± %1
Frequency range46~54Hz or 56~64Hz
Frequency range (batt. mode)50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Output current crest factor3:1 (max.)
THD≤ 2 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
Overload | AC Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload | Battery Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
AC Mode%95.5
Eco Mode%98.5
Battery Mode%94.5
BATTERY
Battery type12V 9Ah
Numbers20 pcs
Charging current (max.)2-12A adjustable
Float charging voltage± 136.5 VDC ±%10
INDICATORS
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Uzun süreli model | Dimension (mm) HxWxD250x630x826
Uzun süreli model | Weight (kg)124 (with internal battery)
ENVIRONMENT
Operating temperature0-40°C
Relative humidity< 95% and non-condersing
Noise level< 60dB @ 1 meter
Managament
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
NOT
(*)As the output voltage is 3 x 360VAC, the output power of the unit will be reduced to 90%.
TECHNICIAL SPECIFICATIONS
Phase3 phase in / 3 phase out
Capacity20kVA / 20kW
Parallel capability3
INPUT
Nominal Voltage3 x 400VAC (3F+N)
Nominal Voltage | Input voltage range190-520VAC (3-Phase) @ 50% load
305-478VAC (3-Phase) @ 100% load
Frequency range46~54Hz or 56~64Hz
Power factor≥ 0.99 @ 100% load
OUTPUT
Output voltage3 x 360*/380/400/415 VAC (3F+N)
AC Voltage regulation± %1
Frequency range46~54Hz or 56~64Hz
Frequency range (batt. mode)50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Output current crest factor3:1 (max.)
THD≤ 2 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
Overload | AC Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload | Battery Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
AC Mode%95.5
Eco Mode%98.5
Battery Mode%94.5
BATTERY
Battery type12V 9Ah
Numbers32 pcs (can be extended with external cabinet)
Charging current (max.)2-12A adjustable
Float charging voltage± 218 VDC ± %10
INDICATORS
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Uzun süreli model | Dimension (mm) HxWxD250x630x826
Uzun süreli model | Weight (kg)139 (with internal battery)
ENVIRONMENT
Operating temperature0-40°C
Relative humidity< 95% and non-condersing
Noise level< 63dB @ 1 meter
Managament
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
NOT
(*)As the output voltage is 3 x 360VAC, the output power of the unit will be reduced to 90%.
TECHNICIAL SPECIFICATIONS
Phase3 phase in / 3 phase out
Capacity30kVA / 30kW
Parallel capability3
INPUT
Nominal Voltage3 x 400VAC (3F+N)
Nominal Voltage | Input voltage range190-520VAC (3-Phase) @ 50% load
305-478VAC (3-Phase) @ 100% load
Frequency range46~54Hz or 56~64Hz
Power factor≥ 0.99 @ 100% load
OUTPUT
Output voltage3 x 360*/380/400/415 VAC (3F+N)
AC Voltage regulation± %1
Frequency range46~54Hz or 56~64Hz
Frequency range (batt. mode)50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Output current crest factor3:1 (max.)
THD≤ 2 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
Overload | AC Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload | Battery Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
AC Mode%95.5
Eco Mode%98.5
Battery Mode%94.5
BATTERY
Battery typeDepends on the application
Numbers32~40 pcs (Adjustable)
Charging current (max.)2-12A adjustable
Float charging voltage±13,65 VxN (N = 16~20)
INDICATORS
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Uzun süreli model | Dimension (mm) HxWxD300x815x1000
Uzun süreli model | Weight (kg)60
ENVIRONMENT
Operating temperature0-40°C
Relative humidity< 95% and non-condersing
Noise level< 65dB @ 1 meter
Managament
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
NOT
(*)As the output voltage is 3 x 360VAC, the output power of the unit will be reduced to 90%.
TECHNICIAL SPECIFICATIONS
Phase3 phase in / 3 phase out
Capacity40kVA / 40kW
Parallel capability3
INPUT
Nominal Voltage3 x 400VAC (3F+N)
Nominal Voltage | Input voltage range190-520VAC (3-Phase) @ 50% load
305-478VAC (3-Phase) @ 100% load
Frequency range46~54Hz or 56~64Hz
Power factor≥ 0.99 @ 100% load
OUTPUT
Output voltage3 x 360*/380/400/415 VAC (3F+N)
AC Voltage regulation± %1
Frequency range46~54Hz or 56~64Hz
Frequency range (batt. mode)50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Output current crest factor3:1 (max.)
THD≤ 2 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
Overload | AC Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload | Battery Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
AC Mode%95.5
Eco Mode%98.5
Battery Mode%94.5
BATTERY
Battery typeDepends on the application
Numbers32~40 pcs (Adjustable)
Charging current (max.)2-12A adjustable
Float charging voltage±13,65 VxN (N = 16~20)
INDICATORS
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Uzun süreli model | Dimension (mm) HxWxD300x815x1000
Uzun süreli model | Weight (kg)61
ENVIRONMENT
Operating temperature0-40°C
Relative humidity< 95% and non-condersing
Noise level< 70dB @ 1 meter
Managament
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
NOT
(*)As the output voltage is 3 x 360VAC, the output power of the unit will be reduced to 90%.
TECHNICIAL SPECIFICATIONS
Phase3 phase in / 3 phase out
Capacity60kVA / 60kW
Parallel capability3
INPUT
Nominal Voltage3 x 400VAC (3F+N)
Nominal Voltage | Input voltage range190-520VAC (3-Faz) @ %50 yük
305-478VAC (3-Faz) @ %100 yük
Frequency range46~54Hz or 56~64Hz
Power factor≥ 0.99 @ 100% load
OUTPUT
Output voltage3 x 360*/380/400/415 VAC (3F+N)
AC Voltage regulation± %1
Frequency range46~54Hz or 56~64Hz
Frequency range (batt. mode)50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Output current crest factor3:1 (max.)
THD≤ 2 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
Overload | AC Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload | Battery Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
AC Mode%95.5
Eco Mode%98.5
Battery Mode%94.5
BATTERY
Battery typeDepends on the application
Numbers32~40 pcs (Adjustable)
Charging current (max.)2-24A adjustable
Float charging voltage±13,65 VxN (N = 16~20)
INDICATORS
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Uzun süreli model | Dimension (mm) HxWxD360x790x1010
Uzun süreli model | Weight (kg)108
ENVIRONMENT
Operating temperature0-40°C
Relative humidity< 95% and non-condersing
Noise level< 70dB @ 1 meter
Managament
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
NOT
(*)As the output voltage is 3 x 360VAC, the output power of the unit will be reduced to 90%.
TECHNICIAL SPECIFICATIONS
Phase3 phase in / 3 phase out
Capacity80kVA / 80kW
Parallel capability3
INPUT
Nominal Voltage3 x 400VAC (3F+N)
Nominal Voltage | Input voltage range190-520VAC (3-Faz) @ %50 yük
305-478VAC (3-Faz) @ %100 yük
Frequency range46~54Hz or 56~64Hz
Power factor≥ 0.99 @ 100% load
OUTPUT
Output voltage3 x 360*/380/400/415 VAC (3F+N)
AC Voltage regulation± %1
Frequency range46~54Hz or 56~64Hz
Frequency range (batt. mode)50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Output current crest factor3:1 (max.)
THD≤ 2 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
Overload | AC Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload | Battery Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
AC Mode%95.5
Eco Mode%98.5
Battery Mode%94.5
BATTERY
Battery typeDepends on the application
Numbers32~40 pcs (Adjustable)
Charging current (max.)2-24A adjustable
Float charging voltage±13,65 VxN (N = 16~20)
INDICATORS
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Uzun süreli model | Dimension (mm) HxWxD360x790x1010
Uzun süreli model | Weight (kg)113
ENVIRONMENT
Operating temperature0-40°C
Relative humidity< 95% and non-condersing
Noise level< 75dB @ 1 meter
Managament
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
NOT
(*)As the output voltage is 3 x 360VAC, the output power of the unit will be reduced to 90%.

NombreTamaño del Archivo
1)TEOS 300 SERIES (10 80 kVA)-